Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
8.
Ann Noninvasive Electrocardiol ; 23(6): e12569, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29947446

RESUMO

BACKGROUND: P-wave duration, its dispersion and signal-averaged ECG, are currently used markers of vulnerability to atrial fibrillation (AF). However, since tangential atrial currents are better detectable at the body surface as magnetic than electric signals, we investigated the accuracy of magnetocardiographic mapping (MCG), recorded in unshielded clinical environments, as predictor of AF occurrence. METHODS: MCG recordings, in sinus rhythm (SR), of 71 AF patients and 75 controls were retrospectively analyzed. Beside electric and magnetic P-wave and PR interval duration, two MCG P-wave subintervals, defined P-dep and P-rep, were measured, basing on the point of inversion of atrial magnetic field (MF). Eight parameters were calculated from inverse solution with "Effective Magnetic Dipole (EMD) model" and 5 from "MF Extrema" analysis. Discriminant analysis (DA) was used to assess MCG predictive accuracy to differentiate AF patients from controls. RESULTS: All but one (P-rep) intervals were significantly longer in AF patients. At univariate analysis, three EMD parameters differed significantly: in AF patients, the dipole-angle-elevation angular speed was lower during P-dep (p < 0.05) and higher during P-rep (p < 0.001) intervals. The space-trajectory during P-rep and the angle-dynamics during P-dep were higher (p < 0.05), whereas ratio-dynamics P-dep was lower (p < 0.01), in AF. At DA, with a combination of MCG and clinical parameters, 81.5% accuracy in differentiating AF patients from controls was achieved. At Cox-regression, the angle-dynamics P-dep was an independent predictor of AF recurrences (p = 0.037). CONCLUSIONS: Quantitative analysis of atrial MF dynamics in SR and the solution of the inverse problem provide new sensitive markers of vulnerability to AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Mapeamento Potencial de Superfície Corporal/métodos , Processamento de Sinais Assistido por Computador , Fatores Etários , Análise de Variância , Fibrilação Atrial/diagnóstico , Estudos de Casos e Controles , Eletrocardiografia/métodos , Feminino , Voluntários Saudáveis , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Valor Preditivo dos Testes , Prognóstico , Valores de Referência , Estudos Retrospectivos , Medição de Risco , Índice de Gravidade de Doença , Fatores Sexuais
9.
J Electrocardiol ; 51(3): 433-439, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29486898

RESUMO

Ventricular arrhythmias (VAs) with left bundle-branch-block and inferior axis morphology (LBBB-IA), suggestive of outflow tract (OT) origin, are a challenge in sports medicine because they can be benign or expression of a silent cardiomyopathy. Non-invasive classification is essential to plan ablation strategy if required. We aimed to evaluating magnetocardiographic (MCG) discrimination of OT-VAs site of origin (SoO). MCG and ECG data of 26 sports activity practitioners, with OT-VAs were analyzed. OT-VAs-SoO was classified with discriminant analysis (DA) of 8 MCG parameters and with invasively-validated ECG algorithms. MCG inverse source-localization merged with magnetic resonance (CMR) provided three-dimensional electro-anatomical imaging (MCG 3D-EAI). ECG classification was univocal in 73%. MCG-DA differentiated right ventricular OT from aortic sinus cusp VAs, with 94.7% accuracy. MCG 3D-EAI confirmed OT-VAs-SoO in CMR images. In cases undergoing ablation, MCG 3D-EAI was confirmed by CARTO 3D-EAI. MCG-DA improves non-invasive classification of OT-VAs-SoO. Further comparison with interventional results is required.


Assuntos
Arritmias Cardíacas/classificação , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/fisiopatologia , Mapeamento Epicárdico/métodos , Sistema de Condução Cardíaco/fisiopatologia , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Magnetocardiografia/métodos , Medicina Esportiva , Adulto , Algoritmos , Fluoroscopia , Humanos , Pessoa de Meia-Idade , Processamento de Sinais Assistido por Computador
10.
Ann Noninvasive Electrocardiol ; 23(3): e12526, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29266621

RESUMO

BACKGROUND: Magnetocardiographic mapping (MCG) provides quantitative assessment of the magnetic field (MF) induced by cardiac ionic currents, is more sensitive to tangential currents, and measures vortex currents undetectable by ECG, with higher reported sensitivity of MCG ventricular repolarization (VR) parameters for earlier detection of acute myocardial ischemia. Aims of this study were to validate the feasibility of in-hospital unshielded MCG and to assess repeatability and reproducibility of quantitative VR parameters, considering also possible gender- and age-related variability. METHODS: MCG of 204 healthy subjects [114 males-mean age 43.4 ± 17.3 and 90 females-mean age 40.2 ± 15.7] was retrospectively analyzed, with a patented proprietary software automatically estimating twelve VR parameters derived from the analysis of the dynamics of the T-wave MF extrema (five parameters) and from the inverse solution with the effective magnetic dipole model giving the effective magnetic vector components (seven parameters). MCG repeatability was calculated as coefficient of variation (CV) ±standard error of the mean (SEM). Reproducibility was assessed as intraclass correlation coefficient (ICC). RESULTS: The repeatability of all MCG parameters was 16 ± 1.2 (%) (average CV ± SEM). Optimal (ICC > 0.7) reproducibility was found for 11/12 parameters (mean values) and in 8/12 parameters (single values). No significant gender-related difference was observed; six parameters showed a strong/moderate correlation with age. CONCLUSION: Reliable MCG can be performed into an unshielded hospital ambulatory, with repeatability and reproducibility of quantitative assessment of VR adequate for clinical purposes. Wider clinical use is foreseen with the development of multichannel optical magnetometry.


Assuntos
Magnetocardiografia/métodos , Função Ventricular/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA